Engel Engel Victus Error Code E1005

Engel Injection Molding Major Temperature

Model: Engel Victus | Code: E1005

Applicable Systems
Engel Victus

Symptoms

The injection molding machine reports high hydraulic oil temperature. The hydraulic system oil exceeds the safe operating limit.

Possible Causes

  • Oil cooler fouled or cooling water insufficient
  • Continuous high-pressure operation generating heat
  • Hydraulic pump internal wear causing inefficiency

Troubleshooting Steps

  1. Step 1: Check the oil cooler and cooling water supply
    Cooler is clean and water flow is adequate
  2. Step 2: Reduce the duty cycle if continuously high load
    Temperature stabilizes
  3. Step 3: Inspect the hydraulic pump for internal wear
    Pump operates efficiently

How to Reset

To reset: Lower the oil temperature below the limit, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Engel Injection Molding Machine Manual, Engel Austria GmbH

Category: Injection Molding