Applicable Systems
Engel Victus
Symptoms
The injection molding machine reports a mold temperature anomaly. The mold temperature controller is outside the setpoint range.
Possible Causes
- Mold temperature controller fault
- Mold cooling water flow insufficient
- Thermocouple or RTD sensor failure
Troubleshooting Steps
- Step 1: Check the mold temperature controller operation
Controller maintains the setpoint - Step 2: Verify mold cooling water flow rate
Flow meets the specification - Step 3: Test the mold temperature sensor accuracy
Sensor reads correctly
How to Reset
To reset: Restore correct mold temperature, then clear the alarm.
Source: Engel Injection Molding Machine Manual, Engel Austria GmbH
Category: Injection Molding