Haitian Haitian Injection Molding Machine Error Code HT008

Haitian Injection Molding Major LimitSwitch

Model: Haitian Injection Molding Machine | Code: HT008

Applicable Systems
Haitian Injection Molding Machine

Symptoms

The Haitian injection molding machine displays alarm HT008, indicating mold open limit switch fault. The mold open position limit switch is not triggering, preventing the machine from completing the mold open cycle or starting the ejection phase.

Possible Causes

  • Limit switch is physically damaged or the actuator cam has shifted position
  • Limit switch wiring is broken or the connector is loose, preventing the signal from reaching the controller
  • Limit switch contacts are oxidized or worn, causing intermittent or no signal

Troubleshooting Steps

  1. Step 1: Inspect the limit switch and actuator cam for physical damage or position shift
    Switch is intact and the cam actuates it at the correct mold open position
  2. Step 2: Check the limit switch wiring and connector for continuity and secure connection
    Wiring is continuous and the connector is tight with no corrosion
  3. Step 3: Test the limit switch contact resistance by actuating it manually and measuring with a multimeter
    Switch closes cleanly when actuated and the contact resistance is near zero ohms

How to Reset

To reset: 1) Replace the damaged limit switch or reposition the cam. 2) Repair wiring and connectors. 3) Replace oxidized contacts. 4) Press RESET. 5) Verify the mold open cycle completes and ejection starts.

Source: Haitian Injection Molding Machine Manual, Haitian International Holdings

Category: Injection Molding