Haitian Haitian Injection Molding Machine Error Code HT010

Haitian Injection Molding Critical Safety

Model: Haitian Injection Molding Machine | Code: HT010

Applicable Systems
Haitian Injection Molding Machine

Symptoms

The Haitian injection molding machine displays alarm HT010, indicating safety door not closed. The safety door has not been detected as closed and locked, preventing the machine from starting or continuing the molding cycle.

Possible Causes

  • Safety door is not fully closed due to an obstruction or a worn door latch mechanism
  • Safety door interlock switch is damaged or misaligned, not detecting the door as closed
  • Safety door interlock wiring is broken or the connector is loose, preventing the interlock signal from reaching the controller

Troubleshooting Steps

  1. Step 1: Verify the safety door is fully closed and the latch engages completely
    Door closes fully and the latch engages with no gap or obstruction
  2. Step 2: Inspect the interlock switch and the actuator key for damage or misalignment
    Switch is intact and the key actuates it at the correct position when the door is closed
  3. Step 3: Check the interlock wiring and connector for continuity and secure connection
    Wiring is continuous and the connector is tight with no corrosion or damage

How to Reset

To reset: 1) Remove any obstruction and repair the door latch. 2) Replace the interlock switch. 3) Repair wiring and connectors. 4) Close the safety door. 5) Verify the machine starts the cycle when the door is closed and locked.

Source: Haitian Injection Molding Machine Manual, Haitian International Holdings

Category: Injection Molding