IPG YLS-2000 Error Code L001

IPG Laser Critical Temperature

Model: YLS-2000 | Code: L001

Applicable Systems
YLS-2000

Symptoms

The fiber laser reports high laser temperature. The laser internal temperature exceeds the safe operating limit.

Possible Causes

  • Cooling water flow insufficient
  • Chiller malfunction or setpoint too high
  • Ambient temperature exceeding the operating range

Troubleshooting Steps

  1. Step 1: Check the cooling water flow rate
    Flow meets the laser specification
  2. Step 2: Verify the chiller operation and setpoint
    Chiller supplies water at the correct temperature
  3. Step 3: Check the ambient temperature in the laser room
    Temperature is between 10 and 35 degrees C

How to Reset

To reset: Lower the laser temperature below the threshold, then reset the alarm.

Source: IPG Fiber Laser User Manual, IPG Photonics Corporation