Konecranes CXT 50t Error Code CR04

Konecranes Crane Major Motor

Model: CXT 50t | Code: CR04

Applicable Systems
SMODEX 90t

Symptoms

The crane reports motor overheating. A hoist or travel motor temperature has exceeded the safe limit.

Possible Causes

  • Motor cooling fan blocked or failed
  • Excessive duty cycle or frequent starts
  • Motor bearing failure generating heat

Troubleshooting Steps

  1. Step 1: Check the motor cooling fan operation
    Fan runs and delivers adequate airflow
  2. Step 2: Verify the duty cycle is within the motor rating
    Operation is within rated duty cycle
  3. Step 3: Inspect motor bearings for noise and heat
    Bearings are in good condition

How to Reset

To reset: Allow the motor to cool, resolve the cause, then reset the protection.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Konecranes Crane Safety Manual, Konecranes Plc