Panasonic MINAS A5 Servo Drive Error Err13.1

Panasonic PLC & VFD Critical Power

Model: MINAS A5 | Code: Err13.1

Applicable Systems
MINAS A5 MINAS A6 MINAS A5II FP-X FP7

Symptoms

The main power supply has an open phase condition detected. One or more phases of the three-phase input are disconnected or have excessive voltage drop.

Possible Causes

  • One phase of the three-phase power supply is disconnected
  • Loose wiring on one or more input phases
  • Faulty circuit breaker or contactor on one phase

Troubleshooting Steps

  1. Step 1: Check all three-phase input voltage at the drive terminals L1, L2, L3
    All three phases measure correct and balanced voltage
  2. Step 2: Inspect wiring connections on all three phases for tightness
    All connections are tight
  3. Step 3: Test the circuit breaker and contactor for proper operation on all phases
    All switching devices operate correctly on all phases

How to Reset

To reset: 1) Restore all three-phase power connections. 2) Cycle power OFF then ON. 3) Re-enable the servo.