Panasonic MINAS A5 Servo Drive Error Err36.0

Panasonic PLC & VFD Critical System

Model: MINAS A5 | Code: Err36.0

Applicable Systems
MINAS A5 MINAS A6 MINAS A5II FP-X FP7

Symptoms

The EEPROM memory that stores drive parameters has detected a data abnormality. This can corrupt parameter settings and prevent normal operation.

Possible Causes

  • EEPROM write cycle was interrupted by power loss
  • EEPROM memory cell degradation due to excessive write cycles
  • Electromagnetic interference corrupted EEPROM data

Troubleshooting Steps

  1. Step 1: Attempt to restore default parameters using the drive panel or PC software
    Parameters are restored to factory defaults
  2. Step 2: Re-enter all application-specific parameters from a saved parameter file
    All parameters are correctly configured
  3. Step 3: If the EEPROM cannot be written, the drive's control board needs replacement
    New control board accepts and retains parameters

How to Reset

To reset: 1) Restore default parameters. 2) Re-configure application parameters. 3) Cycle power. If the error recurs, the EEPROM is damaged and the control board needs replacement.

Frequently Asked Questions

  • Q: What does Err36.0 EEPROM parameter abnormal mean?

    EEPROM memory corruption - try restoring defaults and re-entering parameters. If it recurs, the control board EEPROM is damaged and needs replacement.