Panasonic MINAS A5 Servo Drive Error Err14.1

Panasonic PLC & VFD Critical Hardware

Model: MINAS A5 | Code: Err14.1

Applicable Systems
MINAS A5 MINAS A6 MINAS A5II FP-X FP7

Symptoms

The Intelligent Power Module (IPM) has detected an internal abnormality. This is a hardware-level protection that triggers when the IPM detects over-temperature, over-current, or short circuit within the power semiconductor module.

Possible Causes

  • IPM internal over-temperature due to excessive load or insufficient cooling
  • IPM internal short circuit of IGBT elements
  • Drive cooling fan failure or blocked airflow

Troubleshooting Steps

  1. Step 1: Check the drive cooling fan for proper operation and clean any dust blocking airflow
    Fan operates normally and airflow is unobstructed
  2. Step 2: Reduce the load or duty cycle to bring the drive within rated operating conditions
    Drive operates within rated temperature and current limits
  3. Step 3: If the IPM is damaged internally, the drive must be replaced or sent for repair
    New drive operates without IPM faults

How to Reset

To reset: 1) Allow the drive to cool if overheated. 2) Cycle power OFF then ON. 3) Re-enable the servo. If the alarm returns immediately, the IPM is likely damaged and the drive needs replacement.

Frequently Asked Questions

  • Q: What does Err14.1 IPM abnormal mean?

    The Intelligent Power Module detected an internal fault (over-temperature, short circuit). If it recurs after cooling and power cycle, the drive needs replacement.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Panasonic MINAS A5 Series Servo Drive Manual; Panasonic device FAQ (device.panasonic.cn)

Category: PLC & VFD