Dornier Dornier Weaving Machine Error Code D015

Dornier Textile Major Tension

Model: Dornier Weaving Machine | Code: D015

Applicable Systems
Dornier Weaving Machine

Symptoms

The warp beam tension is fluctuating by more than 5% from the setpoint. The fabric shows tension bars and uneven pick density.

Possible Causes

  • Warp beam tension brake worn or contaminated with oil
  • Tension sensor (load cell) calibration drifted
  • Warp beam axle bearing binding, causing jerky rotation
  • Let-off controller PID parameters incorrectly tuned

Troubleshooting Steps

  1. Step 1: Measure the actual warp tension using a hand-held tension meter
    Compare to the controller reading; if different by more than 5%, recalibrate
  2. Step 2: Inspect the warp beam tension brake for oil contamination
    Clean the brake and check the friction material for wear
  3. Step 3: Rotate the warp beam by hand (machine stopped) and feel for binding
    Replace the beam axle bearing if rotation is not smooth
  4. Step 4: Check the let-off controller PID settings against the commissioning values
    Retune if the parameters have changed or the machine has been modified

How to Reset

Reset: After correction, run at production speed and verify tension stability within 2% of setpoint.

Common Replacement Parts

  • Load cell: Tension type, 0-5000N (Match to loom model and beam width)
  • Brake lining: Friction material, match to brake type (Replace if contaminated or worn)
  • Beam bearing: Spherical roller, match to beam axle (Replace if binding or noisy)

Frequently Asked Questions

  • Q: What is warp tension?

    The longitudinal force applied to the warp yarns during weaving. Correct tension ensures even fabric and prevents yarn breakage. Typical: 20-50 cN per warp end.

  • Q: What causes tension bars?

    Periodic tension variation during let-off. Causes include brake pulsation, bearing binding, and controller tuning issues. Use a tension spectrum analyzer for diagnosis.

  • Q: How often should I calibrate the tension sensor?

    Monthly during production, or after any beam change. Use a calibrated tension meter as reference.

Source: OEM Operation Manual

Category: Textile