Engel Engel Victus Error Code E1013

Engel Injection Molding Major Pressure

Model: Engel Victus | Code: E1013

Applicable Systems
Engel Victus

Symptoms

The injection molding machine reports a back pressure anomaly. The screw back pressure is outside the set range.

Possible Causes

  • Back pressure valve miscalibrated
  • Pressure sensor drift
  • Check ring valve seat worn

Troubleshooting Steps

  1. Step 1: Verify the back pressure valve setting
    Valve is set to the correct pressure
  2. Step 2: Check the pressure sensor calibration
    Sensor reads accurately
  3. Step 3: Inspect the check ring valve seat
    Seat is intact without leakage

How to Reset

To reset: Restore correct back pressure, then clear the alarm.

Source: Engel Injection Molding Machine Manual, Engel Austria GmbH

Category: Injection Molding