Engel Engel Victus Error Code E1013

Engel Injection Molding Major Pressure

Model: Engel Victus | Code: E1013

Applicable Systems
Engel Victus

Symptoms

The injection molding machine reports a back pressure anomaly. The screw back pressure is outside the set range.

Possible Causes

  • Back pressure valve miscalibrated
  • Pressure sensor drift
  • Check ring valve seat worn

Troubleshooting Steps

  1. Step 1: Verify the back pressure valve setting
    Valve is set to the correct pressure
  2. Step 2: Check the pressure sensor calibration
    Sensor reads accurately
  3. Step 3: Inspect the check ring valve seat
    Seat is intact without leakage

How to Reset

To reset: Restore correct back pressure, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Engel Injection Molding Machine Manual, Engel Austria GmbH

Category: Injection Molding