Engel Engel Victus Error Code Er.971

Engel Injection Molding Major InjectionUnit

Model: Engel Victus | Code: Er.971

Applicable Systems
Engel Victus

Symptoms

The servo drive displays Er.971, indicating a DC bus undervoltage warning. The bus voltage has dropped below the warning threshold and is approaching the fault trip level.

Possible Causes

  • Incoming power supply voltage too low or unstable
  • Power supply wiring gauge too small causing voltage drop under load
  • Internal DC bus capacitor degradation reducing bus voltage stability
  • Multiple axes drawing current simultaneously causing bus voltage sag

Troubleshooting Steps

  1. Step 1: Measure three-phase input voltage at drive terminals
    All three phases must be within the rated voltage range of the drive
  2. Step 2: Check power cable sizing and length against drive specifications
    Cable cross-section must be adequate to prevent voltage drop under full load
  3. Step 3: Inspect DC bus voltage using drive diagnostic menu
    Bus voltage should be approximately 1.35x line voltage under normal conditions
  4. Step 4: Verify no excessive loads on the same power circuit
    Dedicated power feed recommended for servo drives

How to Reset

To reset: 1) Restore stable power supply. 2) Power cycle the servo drive. Caution: Operating under undervoltage conditions can cause unpredictable motor control and damage the inverter power stage.

Frequently Asked Questions

  • Q: What voltage level triggers Er.971?

    The warning triggers when the DC bus voltage drops below the warning threshold, typically around 85% of the rated bus voltage.

  • Q: Can I ignore Er.971 if it clears on its own?

    No. Intermittent undervoltage warnings indicate a power supply or wiring problem that will eventually cause a hard fault and production stoppage.

Source: Engel Servo Drive Controller Manual, Alarm Code Reference Er.971, MXA82A-064-503-00/F

Category: Injection Molding