Krones Volumetic VOC 24V Error Code E100

Krones Packaging Major Pneumatic

Model: Volumetic VOC 24V | Code: E100

Applicable Systems
Vodopack 24V

Symptoms

The packaging line reports insufficient air pressure. The compressed air supply pressure is below the minimum required for proper pneumatic component operation.

Possible Causes

  • Main air compressor failure or insufficient capacity
  • Air leak in the supply line or distribution system
  • Air preparation unit pressure regulator set too low

Troubleshooting Steps

  1. Step 1: Check the main air supply pressure at the machine inlet
    Pressure meets the minimum requirement of 6 bar
  2. Step 2: Inspect all air lines and fittings for leaks using soapy water
    No leaks detected at any connection
  3. Step 3: Verify the pressure regulator setting on the air preparation unit
    Regulator is set to the correct pressure

How to Reset

To reset: Restore adequate air pressure, then acknowledge the alarm on the HMI.

Source: Krones Packaging Line Manual, Krones AG

Category: Packaging