Krones Volumetic VOC 24V Error Code E115

Krones Packaging Major Control

Model: Volumetic VOC 24V | Code: E115

Applicable Systems
Vodopack 24V

Symptoms

The packaging line reports a temperature control valve fault. A process temperature control valve is not maintaining the setpoint.

Possible Causes

  • Control valve actuator air supply insufficient
  • Valve positioner out of calibration
  • Temperature controller PID settings incorrect

Troubleshooting Steps

  1. Step 1: Verify air supply to the valve actuator
    Air pressure meets the actuator requirement
  2. Step 2: Calibrate the valve positioner against actual position
    Positioner accurately tracks the control signal
  3. Step 3: Tune the PID parameters for stable temperature control
    Temperature maintains setpoint without oscillation

How to Reset

To reset: Repair the temperature control valve, then clear the alarm on the HMI.