Krones Volumetic VOC 24V Error Code E102

Krones Packaging Major Motor

Model: Volumetic VOC 24V | Code: E102

Applicable Systems
Vodopack 24V

Symptoms

The packaging line reports a motor overload. A drive motor has exceeded its rated current, tripping the overload protection.

Possible Causes

  • Mechanical jam or excessive load on the driven component
  • Motor bearing failure causing drag
  • Incorrect motor parameter settings in the drive

Troubleshooting Steps

  1. Step 1: Inspect the drive train for jams or excessive friction
    Drive train rotates freely without obstruction
  2. Step 2: Check motor temperature and bearing condition
    Motor runs cool with no abnormal bearing noise
  3. Step 3: Verify drive parameter settings match the motor nameplate
    Parameters are correctly configured

How to Reset

To reset: Clear the overload cause, then reset the motor overload relay.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Krones Packaging Line Manual, Krones AG

Category: Packaging