Krones Volumetic VOC 24V Error Code E119

Krones Packaging Critical Safety

Model: Volumetic VOC 24V | Code: E119

Applicable Systems
Vodopack 24V

Symptoms

The packaging line reports a light curtain fault. The safety light curtain is blocked or misaligned, preventing machine operation.

Possible Causes

  • Light curtain beam blocked by an object
  • Light curtain emitter and receiver misaligned
  • Light curtain lens contaminated or damaged

Troubleshooting Steps

  1. Step 1: Inspect the light curtain beam path for obstructions
    Beam path is clear of all objects
  2. Step 2: Check alignment of emitter and receiver units
    Alignment indicator shows correct beam reception
  3. Step 3: Clean the light curtain lenses
    Lenses are clean and beam is received

How to Reset

To reset: Clear the light curtain obstruction, then reset the safety circuit.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Krones Packaging Line Manual, Krones AG

Category: Packaging