Krones Volumetic VOC 24V Error Code E104

Krones Packaging Major Sensor

Model: Volumetic VOC 24V | Code: E104

Applicable Systems
Vodopack 24V

Symptoms

The packaging line reports a sensor anomaly. A proximity, photoelectric, or position sensor is returning invalid or out-of-range signals.

Possible Causes

  • Sensor lens or face contaminated with product residue
  • Sensor mounting loose or bracket bent causing misalignment
  • Sensor element failed or wiring damaged

Troubleshooting Steps

  1. Step 1: Clean the sensor face and check for contamination
    Sensor face is clean and unobstructed
  2. Step 2: Verify sensor alignment to the target
    Sensor detects the target consistently
  3. Step 3: Test sensor output signal and wiring continuity
    Signal is correct and wiring is intact

How to Reset

To reset: Repair or replace the faulty sensor, then clear the alarm on the HMI.

Source: Krones Packaging Line Manual, Krones AG

Category: Packaging