Krones Volumetic VOC 24V Error Code E112

Krones Packaging Major Mechanical

Model: Volumetic VOC 24V | Code: E112

Applicable Systems
Vodopack 24V

Symptoms

The packaging line reports a capping torque overload. The capper torque has exceeded the set limit, tripping the torque monitoring system.

Possible Causes

  • Cap size or type mismatch causing excessive torque
  • Capping chuck spring tension set too high
  • Capping spindle bearing seized or worn

Troubleshooting Steps

  1. Step 1: Verify cap specifications match the product setup
    Cap size and type are correct for the run
  2. Step 2: Check and adjust the capping chuck spring tension
    Torque setting matches the product specification
  3. Step 3: Inspect capping spindle bearings for smooth rotation
    Bearings rotate freely without noise

How to Reset

To reset: Adjust the torque to specification, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Krones Packaging Line Manual, Krones AG

Category: Packaging