Krones Volumetic VOC 24V Error Code E112

Krones Packaging Major Mechanical

Model: Volumetic VOC 24V | Code: E112

Applicable Systems
Vodopack 24V

Symptoms

The packaging line reports a capping torque overload. The capper torque has exceeded the set limit, tripping the torque monitoring system.

Possible Causes

  • Cap size or type mismatch causing excessive torque
  • Capping chuck spring tension set too high
  • Capping spindle bearing seized or worn

Troubleshooting Steps

  1. Step 1: Verify cap specifications match the product setup
    Cap size and type are correct for the run
  2. Step 2: Check and adjust the capping chuck spring tension
    Torque setting matches the product specification
  3. Step 3: Inspect capping spindle bearings for smooth rotation
    Bearings rotate freely without noise

How to Reset

To reset: Adjust the torque to specification, then clear the alarm.

Source: Krones Packaging Line Manual, Krones AG

Category: Packaging