Krones Volumetic VOC 24V Error Code E114

Krones Packaging Major Sensor

Model: Volumetic VOC 24V | Code: E114

Applicable Systems
Vodopack 24V

Symptoms

The packaging line reports a level sensor fault. A tank or vessel level sensor is reading incorrectly.

Possible Causes

  • Level sensor probe contaminated or coated
  • Sensor calibration drifted from reference point
  • Sensor wiring or transmitter fault

Troubleshooting Steps

  1. Step 1: Clean the level sensor probe
    Probe is clean and free of buildup
  2. Step 2: Recalibrate the level sensor against a known reference
    Sensor reads accurately at zero and full scale
  3. Step 3: Test the sensor transmitter output signal
    Signal corresponds to the actual level

How to Reset

To reset: Repair and recalibrate the level sensor, then clear the alarm.

Source: Krones Packaging Line Manual, Krones AG

Category: Packaging