Krones Volumetic VOC 24V Error Code E116

Krones Packaging Major Pressure

Model: Volumetic VOC 24V | Code: E116

Applicable Systems
Vodopack 24V

Symptoms

The packaging line reports low pump station pressure. The process pump discharge pressure is below the minimum required.

Possible Causes

  • Pump inlet strainer clogged restricting suction
  • Pump impeller worn reducing discharge pressure
  • Pump seal leak allowing air ingestion

Troubleshooting Steps

  1. Step 1: Inspect and clean the pump inlet strainer
    Strainer is clean and flow is unrestricted
  2. Step 2: Check pump impeller for wear and erosion
    Impeller is in good condition
  3. Step 3: Verify pump seal integrity and replace if leaking
    Seal is intact with no leakage

How to Reset

To reset: Restore pump pressure to specification, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Krones Packaging Line Manual, Krones AG

Category: Packaging