Krones Volumetic VOC 24V Error Code E113

Krones Packaging Major Valve

Model: Volumetic VOC 24V | Code: E113

Applicable Systems
Vodopack 24V

Symptoms

The packaging line reports a CIP system fault. The clean-in-place system is not operating correctly during the cleaning cycle.

Possible Causes

  • CIP supply pump failure or low flow
  • CIP valve matrix not sequencing correctly
  • CIP solution concentration out of specification

Troubleshooting Steps

  1. Step 1: Check CIP pump operation and flow rate
    Pump delivers the required flow rate
  2. Step 2: Verify CIP valve sequencing against the recipe
    Valves open and close in the correct sequence
  3. Step 3: Test CIP solution concentration with titration
    Concentration meets the cleaning specification

How to Reset

To reset: Resolve the CIP fault, then restart the cleaning cycle from the HMI.