Applicable Systems
PSE200/PSE201

Symptoms

The pneumatic system reports a flow control valve clogged. A speed control or throttle valve is restricted.

Possible Causes

  • Contamination in the air line blocking the throttle
  • Lubricant varnish buildup in the valve
  • Incorrect valve size for the application

Troubleshooting Steps

  1. Step 1: Disassemble and inspect the flow control valve
    Blockage is found and removed
  2. Step 2: Clean the valve with approved solvent
    Valve is clean and flow is restored
  3. Step 3: Verify the valve size is appropriate
    Valve meets the flow requirement

How to Reset

To reset: Clean or replace the flow control valve, then clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: SMC Pneumatic Equipment Manual, SMC Corporation