Robot Fault Codes

1,088 codes
Code Brand Model Error / Alarm Type Severity Action
C50A103 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A103: Voltage failed to reach acceptable level robot Minor View →
C50A104 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A104: The IMMI module does not respond robot Minor View →
C50A11 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A11: Voltage not detected at 24V rail after startup robot Minor View →
C50A16 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A16: The Teach Pendant does not respond robot Minor View →
C50A17 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A17: The Euromap67 interface does not respond robot Minor View →
C50A18 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A18: Warning, waiting for SafetySYS1 robot Critical View →
C50A19 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A19: Warning, Waiting for a valid "euromap67 activated" status bit from secondary robot Minor View →
C50A2 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A2: Voltage present at unpowered robot robot Minor View →
C50A20 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A20: 5V, 3V3 or ADC error (5V too high) robot Major View →
C50A21 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A21: 5V, 3V3 or ADC error (5V too low) robot Major View →
C50A25 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A25: Robot voltage present at 48V PSU powereup robot Minor View →
C50A28 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A28: 12V, 3V3 or ADC error (12V too low) robot Major View →
C50A29 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A29: Analog I/O error (-12V too high) robot Major View →
C50A31 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A31: The other safetySYS do not initialize robot Critical View →
C50A40 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A40: Wrong voltage from PSU1 robot Minor View →
C50A41 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A41: Wrong voltage from PSU2 robot Minor View →
C50A42 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A42: Voltage will not disappear from PSU robot Minor View →
C50A5 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A5: Powersupply voltage too low robot Minor View →
C50A50 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A50: Processor A 3.3V supply voltage out of bounds robot Minor View →
C50A51 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A51: Robot voltage below threshold robot Minor View →
C50A52 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A52: Robot voltage above threshold robot Minor View →
C50A56 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A56: -4V generator too low robot Minor View →
C50A57 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A57: -4V generator too high robot Minor View →
C50A6 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A6: Powersupply voltage too high robot Minor View →
C50A81 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A81: Last CPU reset caused by Window-Watchdog-Reset robot Minor View →
C50A82 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A82: Last CPU reset caused by Independent-Watchdog-Reset robot Minor View →
C50A85 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A85: Last CPU reset caused by Brown-Out-Reset robot Minor View →
C50A99 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C50A99: Wrong software on PCB robot Minor View →
C51A0 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C51A0: Processor B robot Minor View →
C51A1 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C51A1: Primary screen processor robot Minor View →
C51A3 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C51A3: Primary E67 robot Minor View →
C51A4 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C51A4: Secondary E67 robot Minor View →
C526 Universal Robots e-Series (UR3e/UR5e/UR10e/UR16e/UR20/UR30) Universal Robots e-Series Error Code C526: Node ID robot Minor View →
C526A0 Universal Robots e-Series (UR3e/UR5e/UR10e/UR16e/UR20/UR30) Universal Robots e-Series Error Code C526A0: Index/node id {unsigned} is not within the range for a joint. robot Minor View →
C526A1 Universal Robots e-Series (UR3e/UR5e/UR10e/UR16e/UR20/UR30) Universal Robots e-Series Error Code C526A1: Node {unsigned} is not a joint. robot Minor View →
C53 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C53: IO overcurrent detected robot Minor View →
C53A2 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C53A2: , max is 600mA robot Minor View →
C55 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55: Safety system error robot Critical View →
C55A101 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55A101: Safety Channel Error In Safety Control Board robot Critical View →
C55A103 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55A103: Safety Channel Error In Euromap67 Interface robot Critical View →
C55A110 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55A110: Safety State is changing too often robot Critical View →
C55A111 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55A111: On/Off State is changing too often robot Minor View →
C55A120 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55A120: Robot current is too high while emergency stopped robot Critical View →
C55A121 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55A121: Robot current is too high while safeguard stopped robot Minor View →
C55A23 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55A23: Safety relay error (minus connection) robot Critical View →
C55A24 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55A24: Safety relay error (plus connection) robot Critical View →
C55A34 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55A34: Safety relay error (relays are not on) robot Critical View →
C55A51 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55A51: Voltage will not disappear from robot robot Minor View →
C55A53 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55A53: 5V, 3V3 or ADC error (5V too high) robot Major View →
C55A90 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55A90: Bootloader error, robot voltage too low or current too high robot Major View →
C55A91 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C55A91: Bootloader error, robot voltage too high robot Major View →
C56 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C56: Overvoltage shutdown robot Minor View →
C57A1 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C57A1: Joint did not move or motor encoder is not functioning robot Minor View →
C57A2 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C57A2: Large movement detected during brake release robot Minor View →
C58 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C58: Motor encoder not calibrated robot Minor View →
C59 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C59: Overcurrent shutdown robot Minor View →
C60 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C60: Energy surplus shutdown robot Minor View →
C61 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C61: Idle power consumption to high robot Minor View →
C62A1 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C62A1: Joint temperature: High (80(C) robot Minor View →
C62A11 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C62A11: Joint temperature: Shut down (85(C) robot Minor View →
C63 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C63: Motor test failed in step {unsigned}. robot Minor View →
C65 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C65: PSU voltage to high robot Minor View →
C68 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C68: SPI error robot Major View →
C70 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C70: Close to gearbox shear limit robot Minor View →
C71 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C71: Startup check error robot Major View →
C710 Universal Robots e-Series (UR3e/UR5e/UR10e/UR16e/UR20/UR30) Universal Robots e-Series Error Code C710: ROM Test robot Minor View →
C710A0 Universal Robots e-Series (UR3e/UR5e/UR10e/UR16e/UR20/UR30) Universal Robots e-Series Error Code C710A0: Critical error robot Critical View →
C71A0 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C71A0: Hardware is size0, wrong firmware at the joint robot Minor View →
C71A10 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C71A10: Phase 1 is unconnected or not working robot Minor View →
C71A101 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C71A101: Wrong firmware on motor encoder robot Minor View →
C71A11 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C71A11: Phase 2 is unconnected or not working robot Minor View →
C71A12 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C71A12: Phase 3 or multiple phases is unconnected or not working robot Minor View →
C71A2 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C71A2: Hardware is size2, wrong firmware at the joint robot Minor View →
C71A3 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C71A3: Hardware is size3, wrong firmware at the joint robot Minor View →
C71A51 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C71A51: Current sensor test failed robot Minor View →
C71A52 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C71A52: Current sensor test failed robot Minor View →
C71A6 Universal Robots CB3 (UR3/UR5/UR10) Universal Robots CB3 Error Code C71A6: ADC calibration failed robot Minor View →