Pro-face Fault Codes

44 codes

Product Lines:

GP4000 Series
Filter by Category:
Code Model Error / Alarm Category Severity Action
ERR-201 GP4000 Series Pro-face GP4000 Series Error Code ERR-201 hmi Critical View →
ERR-202 GP4000 Series Pro-face GP4000 Series Error Code ERR-202 hmi Major View →
ERR-203 GP4000 Series Pro-face GP4000 Series Error Code ERR-203 hmi Minor View →
ERR-204 SP5000 Series Pro-face SP5000 Series Error Code ERR-204 hmi Major View →
ERR-207 SP5000 Series Pro-face SP5000 Series Error Code ERR-207 hmi Major View →
ERR-209 GP4000 Series Pro-face GP4000 Series Error Code ERR-209 hmi Minor View →
ERR-210 GP4000 Series Pro-face GP4000 Series Error Code ERR-210 hmi Major View →
ERR-211 GP4000 Series Pro-face GP4000 Series Error Code ERR-211 hmi Major View →
ERR-213 GP4000 Series Pro-face GP4000 Series Error Code ERR-213 hmi Critical View →
ERR-214 GP4000 Series Pro-face GP4000 Series Error Code ERR-214 hmi Major View →
ERR-215 GP4000 Series Pro-face GP4000 Series Error Code ERR-215 hmi Minor View →
RHAA006 GP4000/SP5000 Series Pro-face RHAA006: Received data has parity error hmi Major View →
RHAA007 GP4000/SP5000 Series Pro-face RHAA007: Received data has framing error hmi Major View →
RHAA009 GP4000/SP5000 Series Pro-face RHAA009: Cannot use the port hmi Critical View →
RHAA010 GP4000/SP5000 Series Pro-face RHAA010: TCP port number is overlapped or last TCP connection not completed closed hmi Critical View →
RHAA012 GP4000/SP5000 Series Pro-face RHAA012: UDP Port number is overlapped hmi Critical View →
RHAA013 GP4000/SP5000 Series Pro-face RHAA013: COM1 9th pin has not been set to VCC (5V Power Supply) hmi Major View →
RHAA033 GP4000/SP5000 Series Pro-face RHAA033: Error responded for initial communication command hmi Major View →
RHAA034 GP4000/SP5000 Series Pro-face RHAA034: Error responded for device read command hmi Major View →
RHAA038 GP4000/SP5000 Series Pro-face RHAA038: Error responded for device read command (write only devices) hmi Critical View →
RHAA041 GP4000/SP5000 Series Pro-face RHAA041: Illegal response for device read command hmi Major View →
RHAA042 GP4000/SP5000 Series Pro-face RHAA042: Illegal response for device write command hmi Major View →
RHAA043 GP4000/SP5000 Series Pro-face RHAA043: Checksum error response for initial communication command hmi Major View →
RHAA045 GP4000/SP5000 Series Pro-face RHAA045: Checksum error response for device write command hmi Major View →
RHAA049 GP4000/SP5000 Series Pro-face RHAA049: Unknown devices exist in read devices hmi Critical View →
RHAA050 GP4000/SP5000 Series Pro-face RHAA050: Unknown devices exist in write devices hmi Critical View →
RHAA051 GP4000/SP5000 Series Pro-face RHAA051: Out of range devices exist in read devices hmi Critical View →
RHAA052 GP4000/SP5000 Series Pro-face RHAA052: Out of range devices exist in write devices hmi Critical View →
RHAA054 GP4000/SP5000 Series Pro-face RHAA054: Cannot write the read only device hmi Critical View →
RHAA067 GP4000/SP5000 Series Pro-face RHAA067: Response timed out for initial communication command hmi Critical View →
RHAA068 GP4000/SP5000 Series Pro-face RHAA068: Response timed out for device read command hmi Critical View →
RHAA069 GP4000/SP5000 Series Pro-face RHAA069: Response timed out for device write command hmi Critical View →
RHAA070 GP4000/SP5000 Series Pro-face RHAA070: Cable disconnected or target powered off hmi Critical View →
RHAA072 GP4000/SP5000 Series Pro-face RHAA072: Illegal read request because this device has been off scan hmi Major View →
RHAA073 GP4000/SP5000 Series Pro-face RHAA073: Illegal write request because this device has been off scan hmi Major View →
RHAA084 GP4000/SP5000 Series Pro-face RHAA084: Too many requests to write; request ignored hmi Minor View →
RHAA085 GP4000/SP5000 Series Pro-face RHAA085: Too many requests to read; request ignored hmi Minor View →
RHAA088 GP4000/SP5000 Series Pro-face RHAA088: COM1 Multilink station number duplicates another device hmi Critical View →
RHAA089 GP4000/SP5000 Series Pro-face RHAA089: COM1 Multilink communication information address differs from other stations hmi Critical View →
RHAA090 GP4000/SP5000 Series Pro-face RHAA090: Response timed out from external device hmi Major View →
RHAA091 GP4000/SP5000 Series Pro-face RHAA091: COM1 Checksum error response for Multilink command hmi Major View →
RHAA092 GP4000/SP5000 Series Pro-face RHAA092: COM1 Failed to update Multilink communication information hmi Major View →
RHAA093 GP4000/SP5000 Series Pro-face RHAA093: COM1 Cannot join Multilink token; request unreceivable hmi Critical View →
RHAA113 GP4000/SP5000 Series Pro-face RHAA113: Communication system assertion hmi Critical View →