01 01 |
TCM/MC2
|
Door lock contact RK/RKD stuck at floor 01 |
elevator |
High |
View → |
02 02 |
TCM/MC2
|
Group control system fault |
elevator |
High |
View → |
02 03 |
TCM/MC2
|
TCM control system fault |
elevator |
Critical |
View → |
02 04 |
TCM/MC2
|
TCM EPROM fault |
elevator |
Critical |
View → |
02 80 |
TCM/MC2
|
Undefined operation phase |
elevator |
High |
View → |
03 02 |
TCM/MC2
|
Characteristic chip floor error (YY) |
elevator |
Medium |
View → |
03 03 |
TCM/MC2
|
Characteristic chip floor error (NN) |
elevator |
Medium |
View → |
06 01 |
TCM/MC2
|
Door close not achieved at floor 01 |
elevator |
Medium |
View → |
07 01 |
TCM/MC2
|
TSO front door fault |
elevator |
Medium |
View → |
07 02 |
TCM/MC2
|
TSO front door fault (subcode 02) |
elevator |
Medium |
View → |
08 01 |
TCM/MC2
|
TSOD rear door fault |
elevator |
Medium |
View → |
08 02 |
TCM/MC2
|
TSOD rear door fault (subcode 02) |
elevator |
Medium |
View → |
0A 01 |
TCM/MC2
|
Safety device 01: Cabin safety gear trigger |
elevator |
Critical |
View → |
0A 02 |
TCM/MC2
|
Safety device 02: Counterweight safety gear |
elevator |
Critical |
View → |
0A 04 |
TCM/MC2
|
Safety device 04: Rope monitoring |
elevator |
High |
View → |
0A 10 |
TCM/MC2
|
Safety device 10: Car top inspection |
elevator |
Medium |
View → |
0A 20 |
TCM/MC2
|
Safety device 20: Machine room inspection |
elevator |
Medium |
View → |
0B 02 |
TCM/MC2
|
Earthquake sensor triggered |
elevator |
High |
View → |
0C 01 |
TCM/MC2
|
Initialization error - CAN bus |
elevator |
High |
View → |
0C 04 |
TCM/MC2
|
MF3D board fault |
elevator |
High |
View → |
0C 08 |
TCM/MC2
|
MP board fault |
elevator |
High |
View → |
0D 17 |
TCM/MC2
|
Speed monitoring: under-speed detection |
elevator |
High |
View → |
0D 1B |
TCM/MC2
|
Speed monitoring: exceed rated speed |
elevator |
Critical |
View → |
0D 32 |
TCM/MC2
|
Speed monitoring: inspection speed exceeded |
elevator |
Medium |
View → |
0D 34 |
TCM/MC2
|
Speed monitoring: target speed not reached |
elevator |
Medium |
View → |
0D 44 |
TCM/MC2
|
Speed monitoring: speed deviation too large |
elevator |
High |
View → |
0D 52 |
TCM/MC2
|
Speed monitoring: position deviation |
elevator |
High |
View → |
0D 6B |
TCM/MC2
|
Speed monitoring: zero-speed detection failure |
elevator |
Medium |
View → |
0D 8B |
TCM/MC2
|
Speed monitoring: speed monitoring system fault |
elevator |
Critical |
View → |
0E 00 |
TCM/MC2
|
Data transfer fault |
elevator |
High |
View → |
10 YY |
TCM/MC2
|
CPU board fault |
elevator |
Critical |
View → |
12 XX |
TCM/MC2
|
Position mismatch - cabin position error |
elevator |
High |
View → |
14 XX |
TCM/MC2
|
Door lock opened during running |
elevator |
Critical |
View → |
15 XX |
TCM/MC2
|
Position mismatch after correction |
elevator |
Medium |
View → |
17 YY |
TCM/MC2
|
Position mismatch - floor count error |
elevator |
Medium |
View → |
19 NN |
TCM/MC2
|
No floor detected |
elevator |
High |
View → |
1B YY |
TCM/MC2
|
Selector fault - LK sensor |
elevator |
Medium |
View → |
1C NN |
TCM/MC2
|
Selector fault - general |
elevator |
Medium |
View → |
1F 0A |
TCM/MC2
|
MP board communication fault - TMC |
elevator |
High |
View → |
1F 0B |
TCM/MC2
|
MP board communication fault - TMI |
elevator |
High |
View → |
1F 0D |
TCM/MC2
|
MP board communication fault - MQ |
elevator |
High |
View → |
1F 20 |
TCM/MC2
|
MP board communication fault - MQC |
elevator |
High |
View → |
1F 80 |
TCM/MC2
|
MP board communication fault - CAN bus off |
elevator |
Critical |
View → |
20 TT |
TCM/MC2
|
SR module error |
elevator |
High |
View → |
21 00 |
TCM/MC2
|
EEPROM error |
elevator |
High |
View → |
22 00 |
TCM/MC2
|
SR module fault (subcode 00) |
elevator |
High |
View → |
25 02 |
TCM/MC2
|
External call timeout - landing 02 |
elevator |
Medium |
View → |
25 04 |
TCM/MC2
|
External call timeout - landing 04 |
elevator |
Medium |
View → |
25 20 |
TCM/MC2
|
External call timeout - group of landings |
elevator |
Medium |
View → |
2B 00 |
TCM/MC2
|
Stop-start interlock timeout |
elevator |
High |
View → |
2F 00 |
TCM/MC2
|
Re-leveling displacement exceeded 80mm |
elevator |
High |
View → |
30 00 |
TCM/MC2
|
Selector fault during correction run |
elevator |
High |
View → |
3C 00 |
TCM/MC2
|
LK sensor fault |
elevator |
Medium |
View → |
3D 00 |
TCM/MC2
|
LK sensor floor plate fault |
elevator |
Medium |
View → |
3E 00 |
TCM/MC2
|
Anti-crawl device fault |
elevator |
High |
View → |
3F 00 |
TCM/MC2
|
Anti-crawl device fault (variant) |
elevator |
High |
View → |
40 00 |
TCM/MC2
|
Emergency call activated |
elevator |
Low |
View → |
42 00 |
TCM/MC2
|
Run time monitoring exceeded |
elevator |
Medium |
View → |
43 00 |
TCM/MC2
|
Door zone monitoring fault |
elevator |
Medium |
View → |
49 00 |
TCM/MC2
|
Correction run timeout |
elevator |
Medium |
View → |
4A 00 |
TCM/MC2
|
CPU-MW/MW1 communication fault |
elevator |
High |
View → |
4F 00 |
TCM/MC2
|
Contactor check fault |
elevator |
High |
View → |
50 00 |
TCM/MC2
|
TCM recovery run stop collection |
elevator |
Medium |
View → |
EVO-E03 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E03 |
elevator |
Major |
View → |
EVO-E04 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E04 |
elevator |
Major |
View → |
EVO-E05 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E05 |
elevator |
Major |
View → |
EVO-E06 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E06 |
elevator |
Major |
View → |
EVO-E08 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E08 |
elevator |
Major |
View → |
EVO-E09 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E09 |
elevator |
Major |
View → |
EVO-E10 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E10 |
elevator |
Major |
View → |
EVO-E11 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E11 |
elevator |
Major |
View → |
EVO-E12 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E12 |
elevator |
Major |
View → |
EVO-E14 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E14 |
elevator |
Major |
View → |
EVO-E18 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E18 |
elevator |
Major |
View → |
EVO-E19 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E19 |
elevator |
Major |
View → |
EVO-E20 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E20 |
elevator |
Major |
View → |
EVO-E21 |
Evolution
|
ThyssenKrupp Evolution Error EVO-E21 |
elevator |
Major |
View → |